NTC Boresighting & Zeroing
1. Install one 12 volt Lithium battery.
  1. Place battery into battery pouch.
  2. Connect pigtail adapter into the battery.

Display shall read

ENCODER OK
DECODER OK

Followed by two alternating flashing messages which should read

VEHICLE POWER
REQUIRED
KILL BY SYSTEM
POWER ON

2. Vehicles will turn on their Master power switches.

The system will automatically run a BIT test. Display will read

STANDBY NOW
RUNNING BIT TEST

Note: If the VDD displays following messages:

ALERT REPLACE
MILES-2 BATTERY

Proceed with the next step.

3. Turn OFF the Master Power Switches.

4. Disconnect the Lithium battery and turn into OC for a fresh battery.

Follow steps one and two above with new battery.