Table 4-77. Summary of representative bounding accidents under alternative B.a
(per year) | ||||||
RHLWEd release due to a feed line break | High-level | 0.07e | 1.79x10-5 | 6.38x10-7 | 1.32x10-7 | 6.34x10-4 |
RHLWE release due to a design basis earthquake | High-level | 2.00x10-4f | 1.54x10-6 | 5.46x10-8 | 1.12x10-9 | 5.43x10-5 |
RHLWE release due to evaporator pressurization and breech | High-level | 5.09x10-5g | 1.95x10-6 | 3.46x10-8 | 7.13x10-10 | 3.44x10-5 |
Design basis ETFh airborne release due to tornado | High-level | 3.69x10-7i | 3.20x10-13 | 1.02x10-14 | 7.20x10-15 | 6.35x10-14 |
Container breach at the ILNTVj | Low-level
Mixed | 0.02e | 0.00104 | 1.84x10-5 | 3.31x10-7 | 0.0168 |
Large fire at the CIFk | Low-level | 2.34x10-4f | 2.39x10-7 | 7.63x10-9 | 1.64x10-10 | 1.12x10-5 |
Tornado at the ILNTV | Low-level | 2.00x10-5g | 3.26x10-12 | 6.18x10-10 | 1.18x10-10 | 1.18x10-7 |
Explosion at CIF | Low-level | 3.40x10-7i | 1.74x10-10 | 5.54x10-12 | 1.19x10-13 | 8.14x10-9 |
Release due to multiple open containers at the Containment Building | Mixed | 0.003f | 4.69x10-7 | 6.91x10-7 | 1.22x10-8 | 5.70x10-4 |
F3 tornadol at Building 316-M | Mixed | 2.80x10-5g | 5.35x10-12 | 1.29x10-9 | 1.65x10-9 | 1.12x10-9 |
Aircraft crash at the Containment Building | Mixed | 1.60x10-7i | 9.73x10-10 | 3.46x10-11 | 6.66x10-13 | 3.19x10-8 |
Deflagration in culvert during TRUm drum retrieval activities | Transuranic | 0.01e | 8.96x10-4 | 1.59x10-5 | 2.86x10-7 | 0.0145 |
Fire in culvert at the TRU waste storage pads (one drum in culvert) | Transuranic | 8.10x10-4f | 3.07x10-4 | 5.48x10-6 | 9.84x10-8 | 0.0498 |
Vehicle crash with resulting fire at the TRU waste storage pads | Transuranic | 6.50x10-5g | 4.47x10-6 | 7.96x10-8 | 1.43x10-9 | 7.25x10-5 |
a. A complete description and analysis of the representative bounding accidents are presented in Appendix F.
b. Increased risk of fatal cancers per year is calculated by multiplying the [consequence (dose) x latent cancer conversion factor] x annual frequency. For dose consequences and latent cancer fatalities per dose, see tables in Appendix F.
c. The waste type for which the accident scenario is identified as a representative bounding accident. A representative bounding accident may be identified for more than one waste type. These waste types are high-level, low-level, mixed, and transuranic.
d. Replacement High-Level Waste Evaporator.
e. The frequency of this accident scenario is within the anticipated accident range.
f. The frequency of this accident scenario is within the unlikely accident range.
g. The frequency of this accident scenario is within the extremely unlikely accident range.
h. F/H-Area Effluent Treatment Facility.
i. The frequency of this accident scenario is within the beyond-extremely-unlikely-accident range.
j. Intermediate-Level Non-Tritium Vault.
k. Consolidated Incineration Facility.
l. F3 tornadoes have rotational wind speeds of 254 to 331 kilometers (158 to 206 miles) per hour.
m. Transuranic.
NEWSLETTER
|
Join the GlobalSecurity.org mailing list |
|
|