APPENDIX B
DESCRIPTION OF ALTERNATIVES
ACRONYMS AND ABBREVIATIONS
APM
CFR CMPO DOE DST DTPA Ecology EDTA EIS EPA FR HEDTA HEPA HI HLW HMPC HVAC LAW MUST NCRW NEPA NRC PFP PUREX RCRA REDOX SIS SST TBP TFCF Tri-Party Agreement TRUEX TSLCC TWRS WAC WESF WHC WNP-2 |
ammonium phosphomolybdate
Code of Federal Regulations N-diisobutylcarbamoylmethylphosphine oxide U.S. Department of Energy double-shell tank diethylenetriaminepentaacetic acid Washington State Department of Ecology ethylenedianimetetraacetic acid Environmental Impact Statement U.S. Environmental Protection Agency Federal Register hydroxyethylanediamivetriacetic acid high-efficiency particulate air hazard index high-level waste Hanford Multi-Purpose Canister heating, ventilating, and air conditioning low-activity waste miscellaneous underground storage tank neutralized cladding removal waste National Environmental Policy Act U.S. Nuclear Regulatory Commission Plutonium Finishing Plant Plutonium-Uranium Extraction Resource Conservation and Recovery Act Reduction-Oxidation Safe Interim Storage single-shell tank tributyl phosphate tank farm confinement facility Hanford Federal Facility Agreement and Consent Order transuranic extraction Total System Life Cycle Cost Tank Waste Remediation System Washington Administrative Code Waste Encapsulation and Storage Facility Westinghouse Hanford Company Washington Public Power Supply System Nuclear Plant 2 |
NAMES AND SYMBOLS FOR UNITS OF MEASURE, RADIOACTIVITY, AND ELECTRICITY/ENERGY | |||||
Length | Area | Volume | |||
cm | centimeter | ac | acre | cm3 | cubic centimeter |
ft | foot | ft2 | square foot | ft3 | cubic foot |
in | inch | ha | hectare | gal | gallon |
km | kilometer | km2 | square kilometer | L | liter |
m | meter | mi2 | square mile | m3 | cubic meter |
mi | mile | ppb | parts per billion | ||
ppm | parts per million | ||||
yd3 | cubic yard | ||||
Mass | Radioactivity | Electricity/Energy | |||
g | gram | Ci | curie | A | ampere |
kg | kilogram | MCi | megacurie (1.0E+06 Ci) | J | joule |
lb | pound | mCi | millicurie (1.0E-03 Ci) | kV | kilovolt |
mg | milligram | Ci | microcurie (1.0E-06 Ci) | kW | kilowatt |
mt | metric ton | nCi | nanocurie (1.0E-09 Ci) | MeV | million electron volts |
pCi | picocurie (1.0E-12 Ci) | MW | megawatt | ||
V | volt | ||||
W | watt | ||||
Temperature | |||||
C degrees Centigrade | |||||
F degrees Fahrenheit |
This appendix describes the Hanford Site tank waste and cesium (Cs) and strontium (Sr) capsules and the alternatives that are addressed in this Tank Waste Remediation System (TWRS) Environmental Impact Statement (EIS). The detailed description of each alternative includes 1) an overview of the alternative; 2) the facilities to be constructed; and 3) the processes involved. Because certain post-remediation activities are common to each alternative, they are discussed in a separate section followed by a discussion of specific applicable technologies that are not now but could be included in the alternatives. The appendix concludes with a compilation of comparison data such as resource requirements, staffing requirements, and emissions data for each alternative.
This appendix provides specific details about the alternatives to supplement the more general discussion in Volume One, Section 3.0 of the EIS. The data used in generating this appendix came from a series of engineering data packages that were compiled separately by Westinghouse Hanford Company (WHC) and Jacobs Engineering Group Inc. (WHC 1995a, c, d, e, f, g, h, i, j, n and Jacobs 1996).
NEWSLETTER
|
Join the GlobalSecurity.org mailing list |
|
|