The KY-57 VINSON is an auxiliary device used to secure radio transmissions from the AN/VRC-12 series radios and the non-ICOM SINCGARS sets. See Figure 4-11. To encrypt transmissions, it must be loaded with a COMSEC trunk encryption key (TEK) from a KYK-13 or KYX-15. The procedure for loading the KY-57 is as follows--

  • Connect the KY-57 to the radio set.
  • Set the KY-57 to C and fill register to a numbered position/ALL.
  • Turn KY-57 power to ON (COMSEC alarm is heard).
  • Press the handset push-to-talk button twice (COMSEC alarm clears to a steady tone).
  • Set KY-57 mode to LD.
  • Connect KYK-13 to KY-57 using fill cable.
  • Turn KYK-13 to ON and fill register to a numbered position.
  • Press the handset push-to-talk, and a beep is heard and the KYK-13 lamp blinks.
  • Turn KYK-13 OFF and disconnect from the KY-57.
  • Set the KY-57 MODE to C.

Figure 4-11. Loading a KY-57 VINSON fill.

NOTE: The Automatic Net Control Device (AN/CZY-10) will replace the KYK-13, KYX-15, MX-18290, and MX-10579.